Accustream A-6030 Pump

From IkuhluWiki

Jump to: navigation, search

Our Outputs

7-conductor cable from the machine to the pump.

Wire 1
Pump On Signal
Wire 2
Low Pressure Signal
Wire 3
Common
Wire 4
24VDC

Wiring

  1. Connect Wire 2 (Low Pressure) on 7-Conductor cable to 6022 contact block on the pump.
  2. Connect Wire 3 (Common) on 7-Conductor cable to 6022A, 6022E, 6023A, 6023C, TR-1 Term A2, Int-6 Term A2
  3. Connect Wire 4 (24VDC) on 7-Conductor cable to 6023B, INT-6 Terminal 11, TR-1 A1, and TR-1 Term 15
  4. Connect Wire 1 (Pump On) on 7-Conductor cable to INT-6 Terminal A1, and TR-1 Terminal B1
  5. Make sure Int-6 Terminal 12 (Not 14) is connected to 6023
  6. Remove Jumper Between 4063 and 4063A (Remote Stop Button)
  7. Remove Jumper Between 5024A and 5024B (Remote E-Stop)

File:Accustream A-Series Pump.png

Personal tools